EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
125 (200)
f. Click on the adjacent Apply button to modify (if necessary) the Connection
Module Type.
g. For ADSL/POTS card combinations, the “Enable POTS Pass Back” boxes
must be unticked for all ports 1 to 64. To do this quickly then:-
First select Port 1 box and untick it, press and hold down the shift button
and select the Port 64 box. All 64 ports should now be unticked, ie
disabled.
h. Click on the Apply button (next to the ports), then the Refresh button to
confirm that all of the POTS Pass Back boxes are unticked for all ports 1 to
64. Select Close to close down the window.
i. Repeat the steps c to h for other Connection Units where ADSL/POTS
cards combinations are installed.
j. Close down the windows to return to the main LCT screen.