EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
136 (200)
f. Select File” then “Open”, and navigate to the relevant folder to select the
Generic H248 Virtual Gateway file:-
For all sites this will be “Generic H248 VGW Configuration Slots 3 to
21.hvgw”.
g. Select Open” then the H248 Virtual Gateway table will be filled in with
information for all 10 POTS card positions as shown in the following
screen:-
h. The displayed screen .will default to the “Gateway 1” tab.
Note: The “Generic H248 VGW Configuration Slots 3 to 21.hvgw” file
will load data for ten POTS cards, for slots 3, 5, 7, 9, 11, 13, 15, 17, 19 and
21.
i. Identify which slots have POTS cards installed in the node. Then the rows
shown in “Gateway 1” tab which have unequipped POTS cards must be
deleted.
POTS Slot Identifier Outer VLAN ID tag
3 1 151
5 2 152
7 3 153
9 4 154
11 5 155
Blank BlankBlank Blank