EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
154 (200)
Check the Address: shows Slot (as selected), Card Type: ADSLx64, Line:
(as selected).
e. Check the Configuration Profile is set to ADSL2plus_SLOW_BASIC.
Check that only the following three Transmission Mode Type boxes are
ticked:-
ADSL 2+ (G.992.5 over POTS)
ADSL 2 (G.992.3 over POTS)
ADSL (G.992.1 over POTS)
Note: If the Configuration Profile is not set to ADSL2plus_SLOW_BASIC,
or if other Transmission Mode Type boxes are selected instead of the three
types above, then the ADSL lines will need to be reconfigured as described
later. Make a note of the Slot and Line number of any incorrectly configured
lines.
f. Click on the next ADSL Line to be checked.