EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
173 (200)
d. In the TAM Connection Module section select ~ Inward (Interface) Test
radio button. Then click on the Apply button, and click on Yes on the
warning message.
e. Check that the “Current relays position” box displays “Inward Test”.
f. Click on the Refresh button, the radio buttons will be unselected.
g. In the TAM Connection Module section select ~ Normal Operation radio
button, then click on the Apply button. Click on Yes on the warning
message.
h. Check that the “Current relays position” box displays “Normal Operation”.
i. Click on the Refresh button, the radio buttons will be unselected.
j. In the TAM Connection Module section select ~ Outward (Line) Test radio
button. Click on the Apply button and click on Yes on the warning
message.
k. Check that the “Current relays position” box displays “Outward Test”.