EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
175 (200)
Example screen above shows 32 x SHDSL splitter.
c. Check that the correct Slot Card and Connection Module Type is fitted as
specified. Click on the Refresh button, at the bottom of the screen, to
refresh the table if required.
Connection Module Type Unit Code Connection Module Type
shown
64 x ADSL POTS iTAM PB 02HAT00282AAQ cm-adslpotsx64-TAM-PPB
32 x TAM 02HAT00136AAR cm-x32-TAM
Notes: The “Slot Card” shows the Electronic card expected in that slot, the
card may not be fitted. The “Connection Module Type Actual” shows the
currently fitted Connection Module. “dummyConnModule” is the right hand
slot of a double slot Connection Module.
d. Click on the Connection Module ID slot to be checked.
e. Click on the View/Modify Selected Connection Module button.
f. Set the Connection Module Type to cm-adslpotsx64-TAM-PPB for
Connection Module type 02HAT00282AAQ, unless already set correctly.
g. Set the Connection Module Type to unknown for Connection Module type
02HAT00136AAR, unless already set correctly