EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
19 (200)
The front of the card contains the following Interfaces:-
Network Ports - Gigabit Ethernet
There are four Network Gigabit Ethernet sockets, Port 1/1/2/1, Port 1/1/2/2, Port
1/1/2/3, and Port 1/1/2/4, using pluggable SFP modules.
The SFP module types are:-
1000Base-SX 850nm Interface (SU57AD), LC connector.
1000Base-LX 1310nm Interface (SU57AE), LC connector.
1000Base-EX 1310nm Interface (SU57AJ), LC connector.
1000Base-ZX 1550nm Interface (SU57AF), LC connector.
Ethernet Port 10Base-T
This RJ45 socket (5102209-0461) is used to connect to the LAN network, for Out-
Band Management (OBM) and for LCT use during commissioning.
Cabling Note: The Ethernet port can use standard Cat 5 screened cable (Common
Code = 1301042-0019) with standard RJ45 connector (5102169).
Serial Interface Port
This RS-232 RJ12 serial port is not normally used by the on-site engineer for
commissioning, but is utilised in Section 5.2 to download the equipment software to
the CP card’s Compact Flash.
LEDs
The card front is equipped with 3 LED’s whose functions are as follows.
T (yellow) On unit normal activity
Off unit has a protecting role
Blinking configuration is being changed
PWR (green) On unit is powered up
ALARM (red) Off normal activity
On internal alarm.
Blinking external alarm
DIP SWITCH SETTING:-
(Refer to the Section 10 Appendix)
On the Common Part Unit (02HAT00103ACY) check that DIP Switch SW600
(located bottom left near front panel) is set to the default settings, as shown below:-
Pin 1 = OFF
Pin 2 = OFF
Pin 3 = OFF
Pin 4 = OFF
Pin 5 = ON