EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
52 (200)
Do not be alarmed, this message is to be expected.
q. At the command prompt type the following:-
cd<space>/home/Bank1<return>
ls<space>-l
r. Check that “_UP.ID” file is present.
s. At the command prompt type the following:-
mv<space>_UP.ID<space>UP.ID<return>
ls<space>-l
t. Check that “UP.ID” file is present (must be upper case).
u. At the command prompt type the following:-
reboot<return>
v. Wait for the following to be displayed:-
Bank 1: Valid
Active
Bank 2: Not valid
Not active
Running manager
w. Wait for the last message to be displayed, this will be “update Trap
logs……….Trap di CP……..“, at this point press <return> to display
Login:”.
x. The CF download is now complete.