ESTUN AUTOMATION Proprietary
Parameter Description
Angle
Default
0
Range
0.00 to 180.00
Unit
°
Description
Set a desired angle value in the selected bending step.
Corr.α
Default
0
Range
-90.00 to 90.00
Unit
°
Description
This parameter is valid when the bending method is angle, which indicates the
correction on angle to the current bending step . For example:
If the programmed value is 90, while the actual measured value is 92, then
this parameter shall be set to -2.
If
the programmed value is 90, while the actual measured value is 88, then
this parameter shall be set to 2.
Y-axis
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
The programmed value for the Y-axis.
X-axis
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
The programmed value for the X-axis.
Retract
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
Retract distance of the selected axis in the current bend. The "backgauge
retract" is started when the beam is pinching the sheet.
Open
Default
0
Range
0.00 to 99.99 or 0.000 to 9 999.999
Unit
s or mm
Description
Set the opening distance or opening time for the opening process.
Stock
Default
0
Range
-1 to 999 999
Unit
-
Description
The stock counter is incremented or decremented af
ter each end of a program
cycle, which depends on the settings of the parameter Count Mode.
Set it to -1, indicating the stock count is disabled.
Set it to other value:
When the Count Mode is Cnt Down, the stock counter in production
decrease
d by 1 after each product cycle. When the counter has reached 0, the
machine is stopped.
When the Count Mode is Cnt Up, the stock counter in production
increased by 1 after each product cycle.