ESTUN AUTOMATION Proprietary
SingleStep Not Ready Stop
Y:
0.
00
Die
= 1 Y-axis = 0.00 mm
Material = 1 X-axis = 0.00 mm
Thickness = 0.100 mm
Hold Time = 1.00 s
Retr.DLY = 0.50 s
Retract = 0.00 mm
Angle = 150.00 °
Corr.α = 0.00 °
Stock = 50
Single Multi Manual Die Program Constant
Range [
0 ,
30
]
12:
00
X:
0
.00
CP: 1
*
Figure 2-3 The Single-Step page
Table 2-4 lists the description of the parameter on this page. You can refer to this table when you edit
the parameters on this page.
Table 2-4 The description of the parameter on Single-Step page
Parameter Description
Die
Default
1
Range
0 to 30
Unit
-
Description
Set a desired die ID for the program. T
he parameters of the die can be edited
on Die page.
Material
Default
1
Range
1 to 6
Unit
-
Description
Set a desired material ID for the program, which is used for calculat
bending depth. The parameters of the material can be edited on
Table page.
Thickness
Default
0
Range
0.000 to 99.999
Unit
mm
Description
The thickness of the sheet.
Hold Time
Default
0
Range
0.00 to 99.99
Unit
s
Description
The hold (dwell) time of punch at the bending point.
Retr.DLY
Default
0
Range
0.00 to 99.99
Unit
s
Description
The wait time before the X-axis performs the retract.