E300 Operation Manual
Parameters Lists
Document Version: V1.01
ESTUN AUTOMATION Proprietary
VII
Corr.α
Default
0
Range
-90.00 to 90.00
Unit
°
Description
This parameter is valid when the bending method is angle, which indicates the
correction on angle to the current bending step . For example:
If the programmed value is 90, while the actual measured value is 92, then
this parameter shall be set to -2.
If the programmed value is 90, while the actual measured value is 88, then
this parameter shall be set to 2.
Corr.Y
Default
0
Range
-99.99 to 99.99
Unit
mm
Description
Correction on the Y-
axis position, in case absolute programming is used or
bottoming is selected for a bend.
Angle
Default
0
Range
0.00 to 180.00
Unit
°
Description
Set a desired angle value in the selected bending step.
Repeat
Default
1
Range
1 to 99
Unit
Description
Set the repetition times for the selected bending step.
Open
Default
0
Range
0.00 to 99.99 or 0.000 to 9 999.999
Unit
s or mm
Description
Set the opening distance or opening time for the opening process.
Die
Height
Default
0
Range
0.000 to 999.999
Unit
mm
Description
The length from the top to the bottom of the die.
V-width
Default
0
Range
0.000 to 999.999
Unit
mm
Description
The width of the V-opening.
Angle
Default
88
Range
0.00 to 180.00
Unit
°
Description
The angle of the V-opening.
Radius
Default
1
Range
0.000 to 999.999
Unit
mm
Description
The radius of the V-opening edges.