E300 Operation Manual
Parameters Lists
Document Version: V1.01
ESTUN AUTOMATION Proprietary
VI
Default
0
Range
-90.00 to 90.00
Unit
°
Description
This parameter is valid when the bending method is angle, which indicates the
correction on angle to the whole bending. For example:
If the programmed value is 90, while the actual measured value is 92, then
this parameter shall be set to -2.
If the programmed value is 90, while the actual measured value is 88, then
this parameter shall be set to 2.
Steps
Default
1
Range
1 to 25
Unit
Description
This parameter displays how many steps in the selected program.
BN
Default
1
Range
1 to 25
Unit
Description
This parameter indicates the current bending step in the program.
X-axis
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
The programmed value for the X-axis.
Y-axis
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
The programmed value for the Y-axis.
**
R-axis
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
The programmed value for the R-axis.
**
C-axis
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
The programmed value for the C-axis.
Retract
Default
0
Range
0.000 to 9 999.999
Unit
mm
Description
Retract distance of the selected axis in the current bend. The "
backgauge
retract" is started when the beam is pinching the sheet.