E300 Operation Manual
Parameters Lists
Document Version: V1.01
ESTUN AUTOMATION Proprietary
V
Program
Name
Default
Range
The maximum length is 12 characters, which
may contain letters and numbers
as available on the keyboard.
Unit
Description
A unique name to identify a product program.
Die
Default
1
Range
0 to 30
Unit
Description
Set a desired die ID for the program. T
he parameters of the die can be edited
on Die page.
Material
Default
1
Range
1 to 6
Unit
Description
Set a desired material ID for the program, which is used for calculat
ing the
bending depth. The parameters of the material can be edited on
Material
Table page.
Thickness
Default
0
Range
0.000 to 99.999
Unit
mm
Description
The thickness of the sheet.
Hold Time
Default
0
Range
0.00 to 99.99
Unit
s
Description
The hold (dwell) time of punch at the bending point.
Retr.DLY
Default
0
Range
0.00 to 99.99
Unit
s
Description
The wait time before the X-axis performs the retract.
Stock
Default
0
Range
-1 to 999 999
Unit
Description
The stock counter is incremented or decremented af
ter each end of a program
cycle, which depends on the settings of the parameter Count Mode.
Set it to -1, indicating the stock count is disabled.
Set it to other value:
When the Count Mode is Cnt Down, the stock counter in production
mode is
decrease
d by 1 after each product cycle. When the counter has reached 0, the
machine is stopped.
When the Count Mode is Cnt Up, the stock counter in production
mode is
increased by 1 after each product cycle.