ProNet Series AC Servo User's Manual
- 167 -
Parameter
No.
Name Unit
Setting
Range
Factory
Setting
Setting
Invalidation
Pn514
Input port filter 0.2ms 0~1000 1 Immediately
Pn515
Alarm port filter 0.2ms 0~3 1 Immediately
Pn516
Input port signal inversion — 0~1111 0 Immediately
Pn517
Input port signal inversion — 0~1111 0 Immediately
Pn518
Dynamic brake time 0.5ms 50~2000 125 Immediately
Pn519
Serial encoder error time 0.1ms 0~10000 3 Immediately
Pn520
Position complete time 0.1ms 0~60000 500 Immediately
Pn521
If connect externally regenerative resistor
0:connect externally regenerative resistor
between B1 and B2
1:dose not connect externally
regenerative resistor, relay on internal
capacitance
(This parameter is in effect only on
ProNet-02/04
/ProNet-E-02/04)
— 0~1 1 Immediately
Pn522
Reserved — — — —
Pn523
Reserved — — — —
Pn524
Reserved
— — — —
Pn525
Overload alarm threshold % 100~150 100 Immediately
Pn526
Temperature threshold of motor overheat
alarm
(Only enabled in ProNet–75/1A/1E/2B)
℃
50~180 110 Immediately
Pn528 Output signal inverse — 0~1111 0 Immediately
Pn529
Torque detection output signal threshold
value
% 3~300 100 Immediately
Pn530 Torque detection output signal time ms 1~1000 10 After restart
Pn600
Position pulse in point to point control 10000P -9999~9999 0 Immediately
Pn601
Position pulse in point to point control 1P -9999~9999 0 Immediately
……
Pn630
Position pulse in point to point control 1P -9999~9999 0 Immediately
Pn631
Position pulse in point to point control 1P -9999~9999 0 Immediately
Pn632
Point to point speed control rpm 0~3000 500 Immediately
……
Pn647
Point to point speed control rpm 0~3000 500 Immediately
Pn648
Point to point 1st order filter 0.1ms 0~32767 0 Immediately
……
Pn663
Point to point 1st order filter 0.1ms 0~32767 0 Immediately
Pn664
Stop time 50ms 0~300 10 Immediately
……
Pn679
Stop time 50ms 0~300 10 Immediately
Pn680
Reserved
— — — —
Pn681
Hex
Pn681.0:Single/cyclic, start/reference point
— 0~0x0133 0x0000 Immediately