54
ENGLISH
The pump is equipped with a power supply board that regulates the power absorbed as a function of the operating
pressure. (excluding the BASIC series). The following table shows the technical features of the eOne series and the
corresponding flow curves:
Type
Flow at Max Pressure
Pressure
max
[bar]
Setting
[imp/1’]
Electric
Power supply
Power
[W]
Current
MAX
[A]
Weight
[kg]
L/h mL/min
mL/str
oke
0110
1 (0.26)
16,66
0,09
10 (145)
0 180
100 -250 V
50-60 Hz
19
1.4
3.0
0216
2 (0.53)
50,00
0,11
16 (232)
0 300
21
1.4
3.5
0420
4 (1.06)
83,33
0,22
20 (290)
0 300
21
1.4
3.0
0607
6 (1.59)
83,33
0,33
7 (101)
0 300
28
2.0
4.5
0710
7 (1.84)
133,33
0,39
10 (145)
0 300
26
1.8
3.5
1012
10 (2.64)
166,66
0,56
12 (174)
0 300
36
1.8
4.5
1505
15 (3.96)
250,00
0,83
5 (72)
0 300
26
1.8
3.5
2007
20 (5.26)
333,33
1,11
7 (101)
0 300
32
1.9
4.7
3005
30 (7.92)
500,00
1,66
5 (72)
0 300
32
1.9
4.7
0210(*)
2 (0.53)
33,33
0,18
10 (145)
0 180
36
1.6
3.0
0507(*)
5 (1.32)
83,33
0,46
7 (101)
0 - 180
36
1.6
3.0
(*) BASIC model only
The values shown are with a tolerance of + / - 5%, and relate to a series of tests carried out on similar equipment
with water at a temperature of 20 ° C.