Error Codes 28
Gobo 2
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
Gobo Wheel 2 is not located in the default position after the reset
Gobo Rot 1
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
Gobo Rotating Wheel 1 is not located in the default position after the reset
Iris
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the Iris is not located in the default position after the reset
Pan
This message displays after the reset of the fixture if any of the following conditions exist:
the yoke’s magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the Pan movement is not located in the default position after the reset
Prism 1
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
Prism wheel 1 is not located in the default position after the reset
Prism 2
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
Prism wheel 2 is not located in the default position after the reset
Prism_Rot 1
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
Prism rotating wheel 1 is not located in the default position after the reset