EasyManua.ls Logo

EUCHNER CTS-C1-BP-FLX - With Inactive Guard Lock Monitoring

EUCHNER CTS-C1-BP-FLX
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Transponder-Coded Safety Switch CTS-C1-BP/BR-FLX
8
(translation of the original operating instructions) MAN20001587-01-02/23
3.2. With inactive guard lock monitoring
Monitoring of the guard position
(interlocking device according to ENISO14119)
Ì Safety function: the safety outputs are switched off when the guard is open (see chapter 6. Function on page
10).
Ì The safety functions are ensured only if the actuator is mounted properly (see chapter 8. Mounting on page 15).
Ì Safety characteristics: category, Performance Level, PFH
D
(see chapter 16. Technical data on page 40).
The following additionally applies in a BR series connection:
Ì The safety outputs are switched on only when the device receives a corresponding signal from its predecessor in the chain.
NOTICE
You can regard the complete BR device chain as one subsystem during calculation. The following
calculation method applies to the PFH
D
value:
#1
PFH
D,1
PFH
D,ext
BR-Device #1 ... n External Evaluation
(e.g. PLC)
PFH
D
ges =∑ PFH
D,k
+ PFH
d,ext
n
k=1
#2
PFH
D,2
#n
PFH
D,n
Alternatively, the simplied method according to section 6.3 of ENISO13849-1:2015can be used
for calculation.