XRF1/XRF1A 16x16 RF Router Manual
XRF1 - 6-2 Revision 1.2 VISTALINK
6.1.3. Specifications
6.1.3.1. Serial I/O (COM 1)
Standard: RS-232
Connector: Female DB-9
Baud Rate: 57600
Format: 8 bits, no parity, 2 stop bits, no hardware flow control (COM2 not available)
6.1.3.2. Ethernet I/O
Standard: IEEE 802.3 (10BaseT), IEEE 8002.3u (100BaseTx)
Connector: 1 RJ45
Cable Requirements:
10 Base T: UTP category 3, 4 or 5 cable up to 328ft/100m (2 pairs)
100 Base Tx: UTP category 5 cable up to 328ft/100m (2 pairs)
6.1.3.3. Electrical
Voltage: 100-240VAC, 50/60 Hz auto-ranging
Power: 11 Watts
EMI/RFI: Complies with FCC Part 15, class A and EU EMC directive.
6.1.3.4. Physical
Size: 17 1/8” W x 4 3/8” D x 3 ½” H (435mm x 111mm x 89mm)
Weight: 4 lbs. (1.81 kg)
Temperature: 0 to 50 deg. C. (Operating)
6.1.4. X-NCP2 Configuration Menu
When power is applied to the unit, the X-NCP2 provides a set-up menu with the following parameters:
<back> Conveniently located at the start and end of a menu stack, this menu item allows the
user to return to the previous menu for further configuration, if required.
Network Setup: Set the IP address of the X-NCP2 unit, its subnet mask and gateway IP.
Configuration: N/A
Service: N/A
Reboot: A menu option that allows the user a quick way to reboot the X-NCP2 unit without
unplugging the AC power source from the unit. Options are “yes” and “cancel”.
Discovery: N/A
Add Frame: Menu option to add routers to the X-NCP2 control list
Remove Frame: Menu option to remove routers from the available list.
Request update: N/A