EX-2001 Plus v1.3 SME300000060
43
EXCELL PRECISION CO., LTD.
9-6 OP-08 CONTROL I /O (2I /4O) INTERFACE FUNCTION
SET VALUE FUNC.
NO.
FUNCTION
PARAMETER
DESCRIPTION
DEFAULT
FUNC. 50
Input 1 1
FUNC. 51
Input 2
0 No capacity
1 Zero
2 Tare
3 Clear Tare
4 judgment_comm_flag
2
0000
Positive logic
FUNC. 52
Output logic
1111
Negative logic
0000
0 Comparison occurs at any time
1
Comparison occurs after inputting
external judgment signal
FUNC. 53
Hi,OK,Lo
Check weighing
mode
2 Auto comparison
0
0 General comparison +
FUNC. 54
Comparison mode
1 Absolute value only comparison +/-
0
FUNC. 55
Lead time setting
for activating
comparison
0.0
25.5
Lead time setting for inputting
external judgment
signal
0.5