73
04011210
EXCELL PRECISION CO., LTD
ZSME400000003
Function code 06: Modbus (41026): write batch finish delay time write
Name Input Description Name Output Description
ID Address 01 Machine ID ID Address 01 Machine ID
Function
code
06
Function
code
06
04 04
Register's
address
02
Batch Finish delay
time address
1026
(10)
= 04 02
(HEX)
Register's
address
02
Batch Finish delay
time address
1026
(10)
= 04 02
(HEX)
00 00
Setting
value
07
Input value 7s
is 0007
(HEX)
Setting
value
07
Input value 7s
is 0007
(HEX)
xx xx
CRC
xx
CRC
xx
Function code 01: Modbus (00000~00001): read current scale status
Name Input Description Name Output Description
ID Address 01 Machine ID ID Address 01 Machine ID
Function
code
01
Function
code
01
00
Register's
address
00
Starting Address Bit 02
Read 2 Bit data:
2=10
(2)
, 00001 = 1
(return to zero) or 0
(non return to zero),
00000 = 0 (stable) or
1 (unstable)
00
Setting
value
02
Read 2 status (2 Bit)
00000~00001
BD D0
CRC
CB
CRC
49