70
04011210
EXCELL PRECISION CO., LTD
ZSME400000003
Appendix 3 MODBUS Data Address Table I
Data Register Bit I/O Bit I/O
Function Code 03 (Read
)
Function Code 01 (Read) Function Code 05 and 15 (Write)
Modbus SCALE Modbus SCALE Output Modbus SCALE Input
40000 ~ 40001 As display value 00000 Stable status 01000 Zero
40002 ~ 40003 Gross weight 00001 Zero status 01001 Clear zero compensation
40004 ~ 40005 Net weight 00002 Gross 01002 Tare
40006 ~ 40007 Tare weight 00003 Net 01003 Clear Tare
40008 ~ 40009
Gross weight
hold value
01004 Clear Pre-tare
40010 ~ 40011
Net weight
hold value
00050 Zero Band 01005
Display the gross weight on
main display
40012 ~ 40013
Weight final
value
00051 Sp1 01006
Display the net weight on
main display
40014 ~ 40015 Unit weight 00052 Sp2 01007
Enter/Exit the function
mode
40016 ~ 40017
Percentage
value
00053 Sp3
01008 ~ 01027
Switch unit
from the 1
st
to 20
th
40018 ~ 40019 Totalised value 00054 Batch Finish
40020 ~ 40021 Totalised times 00055 Under 01049 Switch the operation modes
40022 ~ 40023
Totalised times
of HI value
00056 Over 01050
Totalised the current net
weight and add 1 to the
totalised times
40024 ~ 40025
Totalised times
of Lo value
00057 Unloading 01051
Deduct the last totalised
value and deduct 1 to the
totalised times
40026 ~ 40027
Totalised times
of OK value
00058 Hi-Hi 01052
Clear the totalised value
and times
00059 Hi 01053 Running
Function Code 06 and 16 (Write)
00060 Go 01054 Stop
41000 ~ 41001 Pre-tare value 00061 Lo 01055 Discharge starts
41002 ~ 41003 Zero Band value 00062 Lo-Lo 01056 Hold mode ON/OFF
41004 ~ 41005 Target value 00063 Peak ready 01057 Release "Hold value"
41006 ~ 41007 SP1 value 00064 Running 01058 Output judgement
41008 ~ 41009 SP2 value 00065 ZERO calibration 01059 ZERO calibration
41010 ~ 41011 SP3 value 00066 SPAN calibration 01060 SPAN calibration
41012 ~ 41013 LO_LO value 00067 Calibrate ERR0
41014 ~ 41015 LO value 00068 Calibrate ERR2
41016 ~ 41017 HI_HI value 00069 Calibrate ERR6
41018 ~ 41019 HI value
41020 ~ 41021 Under value
41022 ~ 41023 Over value
41024 ~ 41025
Peak value
setting
41026 ~ 41027
Batch Finish
delay time
41100 ~ 41101
SPAN calibration
value

Table of Contents