SSP 200 • SIS Configuration and Control 66
X1$
= Stop bits: 1, 2 (default=1)
X1%
= Port type: 0=RS232, 1=RS422, 2=RS485 (default=0=RS232)
X1^
= Flow Control: Hardware, Software, None [only use the first letter] (default=N=None).
X1&
= Data Pacing [specified in milliseconds between bytes]: 0000 to 1000 (default=0 ms). For
host port(s), this value is ignored – always returns 0.
X1(
= GMT offset value: This represent hours and minutes (hh:mm) offset from Greenwich Mean
Time.
X2)
= DHCP status
0 = Off (default)
1 = On
X2!
= Unit name: A text string up to 63 characters drawn from the alphabet (A to Z),digits (0 to 9),
and minus sign/hyphen (–).
X2@
= Local date and time format: MM/DD/YY-HH:MM:SS
X2#
= IP Address: xxx.xxx.xxx.xxx . Leading zeros in each of the 4 fields are optional in setting
values and are suppressed in responses.
X2$
= Hardware MAC address: 00-05-A6-xx-xx-xx
X2%
= Subnet mask: xxx.xxx.xxx.xxx . Leading zeros in each of the 4 fields are optional in
setting values and are suppressed in responses.
X2^
= NIC number: Network Interface Card number 1 or 2.
X2&
= Prefix (subnet mask bits): Subnet 255.255.0.0 is represented as a prefix value of /16.
X2*
= Date/Time returned in 7 Hex bytes month, day, year, hour minutes, seconds, day of the
week (1 begins on Sunday).
X2(
= NTP service mode
0 = Disable
1 = Enable
X3)
= Default name: Combination of model‑name and last 3 pairs of MAC address (for example:
SSP-200-00-02-3D).
X3!
= Password: Password: Up to 128 characters. All man‑readable characters are permitted
except “|”. Password cannot be a single space. Passwords are case‑sensitive.
X3@
= Responds with 4 asterisks (****) if password exists and empty if not, instead of actual
password.
X3#
= Connection security level
11 = User
12 = Administrator
X3&
= Device temperature (degrees Celsius)
X3*
= Verbose/response mode
0 = Clear/none (IP default)
1 = Verbose mode (USB default)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
X4)
= Serial Host‑control port mode:
0 = Device Control (no SIS)
1 = Standard Host control (SIS ‑ default)
2 = Disable Port
X4!
= Connection status
1 = Connected
2 = Not Connected
X4@
= Input number: 1 to 5.
X4#
= EXP assignment (HDMI and analog inputs are unavailable for EXP assignment):
0 = EXP off (default)
2 = Input 2
3 = Input 3
4 = Input 4