SSP 200 • SIS Configuration and Control 67
X4$
= EXP input channel pair:
1 = EXP Input 1 & 2 5 = EXP Input 9 & 10
2 = EXP Input 3 & 4 6 = EXP Input 11 & 12
3 = EXP Input 5 & 6 7 = EXP Input 13 & 14
4 = EXP Input 7 & 8 8 = EXP Input 15 & 16
X4%
= Source format:
0 = Not present 7 = Dolby TrueHD ATMOS
1 = Analog 8 = DTS or DTS 96/24
2 = PCM 9 = DTS‑ES (96/24, Matrix, or Discrete)
3 = Dolby Digital/EX 10 = DTS‑HD High Resolution Audio
4 = Dolby Digital Plus 11 = DTS‑HD Master Audio
5 = Dolby Digital Plus ATMOS 12 = DTS Express
6 = Dolby TrueHD 13 = DTS:X
X4^
= Decoded Sampling Rate
0 = None 4 = 88.2 kHz
1 = 32 kHz 5 = 96 kHz
2 = 44.1 kHz 6 = 176.4 kHz
3 = 48 kHz 7 = 192 kHz
X4&
= Source Encoded Channels (Front, Center, Surround, Back, Subwoofer, Height)
0 = None 8 = 4.1
1 = 1.0 9 = 5.0
2 = 1.1 10 = 5.1
3 = 2.0 11 = 6.0
4 = 2.1 12 = 6.1
5 = 3.0 13 = 7.0
6 = 3.1 14 = 7.1
7 = 4.0
X4*
= Signal Status:
0 = Signal not detected
1 = Signal detected
X4(
= Input HDCP status:
0 = No source is detected
1 = Source is detected with HDCP
2 = Source detected without HDCP
X5)
= Enable or Disable:
0 = Disable
1 = Enable (default)
X5#
= HDMI Loop Out mode:
0 = No audio
1 = Follow input
2 = Downmix (Default)
X5$
= Output HDCP status:
0 = No sink detected
1 = Sink detected with HDCP
2 = Sink detected without HDCP
X5%
= Output HDCP mode:
1 = Auto: Encrypt as required by input. Continuous trials for HDMI sinks (Default)
2 = Always Encrypt Output. Continuous trials for HDMI sinks
X5&
= Output channel (channels 7 to 10 change depending on layout and downmix settings):
1 to 10 or 15 to 16.

Table of Contents