SSP 200 • SIS Configuration and Control 72
Command SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
Port Assignment (continued)
Disable FTP port
EF0PMAP} PmapF00000]
View FTP port map
EFPMAP} {port#}]
Set TFTP port map
ET{port#}PMAP} PmapT{port#}]
Reset TFTP port map
ET69PMAP} PmapT00069]
Disable TFTP port
ET0PMAP} PmapT00000]
View TFTP port map
ETPMAP} {port#}]
Simple Network Management Protocol (SNMP)
Set unit contact
ECX12)SNMP} SnmpC*X12)]
Set unit contact to
default
EC•SNMP} SnmpC*Not•Specied]
View unit contact
ECSNMP} X12)]
Set unit location
ELX12)SNMP} SnmpL*X12)]
Set unit location to
default
EL•SNMP} SnmpL*Not•Specied]
View unit location
ELSNMP} X12)]
Set community public
(read‑only)
EPX12)SNMP} SnmpP*X12)]
Set community public to
default
EP•SNMP} SnmpP*public]
View community public
EPSNMP} X12)]
Set community private
(read/write)
EXX12)SNMP} SnmpX*X12)]
Set community private to
default
ESnmpX*X12)} SnmpX*private]
View community private
EXSNMP} X12)]
Enable SNMP access
and traps
EE1SNMP} SnmpE*1]
Disable SNMP access
and traps
EE0SNMP } SnmpE*0]
View SNMP access
setting
EESNMP} X2(]
Set trap target
ETX12),X12!*X2#*X12@
SNMP}
SnmpT*X12),X12!*X2#* X12@]
Remove trap target
ETX12!*0SNMP} SnmpT*,X12!*0.0.0.0*0]
View trap target
ETX12!SNMP} X12),X2#*X12@]
KEY:
X2#
=
IP Address: xxx.xxx.xxx.xxx . Leading zeros in each of the 4 fields are optional in setting values and are
suppressed in responses.
X2(
=
NTP service mode: 0 = Disable 1 = Enable
X12)
=
Text – up to 64 characters
X12!
=
SNMP Trap target number (1 to 3)
X12@
=
SNMP Trap version for target (2 or 3)

Table of Contents