Dip 1 Dip 2 Dip 3 Dip 4 Pair
no.
Type
ON OFF OFF OFF
1°Pair
CLOSE
photocells
ON OFF OFF ON
2°Pair
ON OFF ON OFF 3°Pair
ON OFF ON ON 4°Pair
ON ON OFF OFF 5°Pair
ON ON OFF ON 6°Pair
ON ON ON OFF 7°Pair
ON ON ON ON Single OPEN
PULSE
DIP-SWITCH
TX
DIP-SWITCH
RX
SAME
ADDRESS
4.1.2 Connecting BUS photocells
Up to 8 pairs of photocells can be connected to the E680 control board
using BUS technology.The connection must be made in parallel,
onterminalboardJ6,usingasinglepower/communicationline,as
showninFig.27.
BUS photocells do not require a matching polarity
connection.
The8pairsofphotocellsfeaturethefollowingfunctions:
Pairsofclosingphotocells: max7
PairsofOPENpulsephotocells: max1
After positioning the BUS technology photocells, it is necessary
toproceed with selecting the address foreach pair using various
combinations of the DIP-SWITCHES located on each photocell.
Set the SAME DIP-SWITCH ADDRESS chosen both on
the transmitter and receiver of the same pair.
Ensure that two or more pairs of photocells do not have
the same address. If no BUS accessories are used, leave
terminals 1 and 2 free.
Thefollowing table describeshow to set thedip-switches located
inside the transmitter and receiver of the BUS photocells.
Addressing BUS photocell PAIRS
To allow operation of the installed BUS accessories,
store them on the board as described in paragraph 5.3.
4.2 Terminal board J2 (outputs)
OUT 1 - Output 1 open-collector GND (terminal 13):Theoutputcan
besetinoneofthefunctionsdescribedintheAdvancedConfiguration
(par. 6).The default value is 04
- Beam OPEN or in PAUSE.
Maximum load: 24 VDC with 100 mA.
OUT 2 - Output 2 open-collector GND (terminal 15):
Theoutputcan
besetinoneofthefunctionsdescribedintheAdvancedConfiguration
(par.6).Thedefaultvalueis03
- CLOSED BEAM. Maximum load:
24 VDC with 100 mA.
OUT 3 - Output 3 open-collector GND (terminal 17):
Theoutputcan
besetinoneofthefunctionsdescribedintheAdvancedConfiguration
(par.6).Thedefaultvalueis19
-WARNINGLAMP.Maximum load:
24 VDC with 100 mA.
OUT 4 - Relay output 4 (terminals 19, 20, 21): Theoutputcanbe
setinoneofthefunctionsdescribedinAdvancedConfiguration(par.
6).Thedefaultvalue is01
- BEAM ILLUMINATION. Maximum
load: 24 VDC with 800 mA.
4.3 Terminal board J3 (external ashing lamp)
LAMP:tothese terminals you can connect a 24VDC FAACLED
externalflashinglamp.The integrated flashing traffic light must be
connected independently to connector J15.
The 24V FAACLIGHT with incandescent lamp cannot be
connected to the J3 connector
4.4 Terminal board J4 (loop detector)
LOOP 1: magneticloop LOOP1(OPEN,terminals 24-25): for
OPENING.
LOOP 2:
magneticloopLOOP2(SAFETY/CLOSE,terminals26-27):
for SAFETY/CLOSING.
4.5 Connector J5 (Motor)
Rapidconnectorforconnectingthemotor.
4.6 Connector J7 (Encoder)
TheB680Hbarrierisequippedwithadevicefordetectingtheopening
angle/barpositiontoensuregreateranti-crushingsafetythanksto
thepossibilityofreversingthedirectionofmovementthemomentin
which an obstacle is detected. This device interfaces with the board
throughconnectorJ7.
4.7 Connector J10 (Radio)
UsedfortherapidconnectionoftheMinidec,DecoderandRP/RP2
Receivers(seeFig.28).Ifa2-channelreceiverisused,liketheRP2,
itwillbepossibletodirectlycommandautomatedsystemOPENand
CLOSEfroma2-channelradiocontrol.Ifa1-channelreceiverisused,
liketheRP,itwillonlybepossibletocommandOPEN.
Connecttheaccessory withthecomponents sidefacingthe main
strip of the board.
Boards should be inserted and removed ONLY after
having cut off electrical power
4.8 Connector J11 (Beam break-out sensor)
Designedforconnectingthebreak-outsensorforthepivotingbeam
(ifpresent).Thesensorisoptional.Ifitisnotpresent,do not remove
theinstalledjumper.
4.9 Connector J12 (Emergency battery)
Thisconnectoris for connecting a battery (optional) for ensuring
automatedsystemoperationincaseoftemporarycutoffofthemain
powersupply.
4.10 Connector J13 (36VDC Power Supply)
Thisfactory-wiredconnectorpowerstheE680board
4.11 Connector J15 (ashing trafc light)
Thisconnectorisforconnectingthe flashing traffic light built into
the barrier head.The flashing traffic light visually signals barrier
movementand,ifneeded,regulateaccess to the property using
trafficlightsignals.