Changes  to  the  conguration  parameters  become 
effective immediately, while final storage occurs
only  upon  exiting  conguration  and  returning  to  the 
automated system status display. If the equipment is
powered down before returning to the automated system
status display, all changes made will be lost.
5.1 Basic conguration
ToperformBASICprogramming:
1. Pressandholdbutton F; the name of the first function is
displayed.
2. Releasethebutton;thefunctionvalueisdisplayedandcanbe
modifiedusingthe+and-buttons.
3. Press and hold Fagain;thenameofthefollowingfunctionis
displayed,andsoon.
ThelastfunctionStletsyouchoosewhethertosavetheconfiguration
made(Y)orexitwithoutsaving(no).Later,thedisplaywillresume
showingtheautomatedsystemstatus
You can go to St at any time. To exit programming,
simultaneously press F and -.
BASIC CONFIGURATION
Display
Function Default
dF
Loading predefined parameter sets
00 Neutralcondition
01 Minimummass
06 Maximummass
Beforeautomatedsystemstart-up,youmust
setthecorrectvalue,directlycorrelatedtothe
lengthofthebeamandthenumberandtype
of accessories installed. To determine said
value,refertoTables4and5onpage24
WARNING: Setting a mass default
lower than the one actually
installed could cause irreversible
damage to the bar and barrier
structure.
Ifyoudonotwishtomakeanyprogramming
changes, leave the value 00, otherwise
selectingavalueinvolvesloadingthechosen
predefined parameters set (see paragraph
5.2).
00
At
Currently loaded default
This menu indicates the currently loaded
defaultsetting.
Given that parameter dF has 00 as the
predefinedvalue(inordertoprovideaneutral
accessconditiontotheparameters),usingthe
valueinthismenumakesitpossibletoidentify
thecurrentlyconfigureddefaultsetting.
Read-only parameter
06
Display
Function Default
bu
BUS accessories menu
Forfunctionsassociatedwiththisparameter
seeparagraph5.3
no
LO
Operating logics
A Automatic
A1 Automatic1
E Semi-automatic
P Parking
PA Automaticparking
Cn Condo
CA Automaticcondo
C Dead-man
CU Custom
E
PA
Pause time
Is effectiveonly if an automatic logic is
chosen;thevalue can be set from O to
59 sec. in one second steps.Next,the
displaychangestominutesandtenthsofa
second(separatedbyadecimalpoint) and
timeisadjustedin10-secondstepsuptothe
maximumvalueof4.1minutes.
e.g.ifthedisplayshows2.5,thepausetime
willbe2minutesand50seconds.
20
So
Opening speed
Adjuststhebarrieropeningspeed.
00 Minimumspeed
10 Maximumspeed
WARNING: Setting an excessive speed
could cause irreversible damage to the
beam and barrier structure.
10
Sc
Closing speed
Adjuststhebarrierclosingspeed.
00 Minimumspeed
10 Maximumspeed
WARNING: Setting an excessive speed
could cause irreversible damage to the
bar and barrier structure.
02
L1
Loop 1
Activatingthisparameter,anyloopthatis
connectedtotheLoop1inputwillserveas
anOPENfunction.
Y Loop 1 enabled
no Loop 1 disabled
Note:Shouldthisfunctionbe disabled, the
detectionstatusoftheloopwillinanycase
remainavailableononeofthetwooutputs,
ifconfigured(see parameters o1... o4 in
AdvancedConfiguration)
no