Changes to the conguration parameters become
effective immediately, while final storage occurs
only upon exiting conguration and returning to the
automated system status display. If the equipment is
powered down before returning to the automated system
status display, all changes made will be lost.
5.1 Basic conguration
ToperformBASICprogramming:
1. Pressandholdbutton F; the name of the first function is
displayed.
2. Releasethebutton;thefunctionvalueisdisplayedandcanbe
modifiedusingthe+and-buttons.
3. Press and hold Fagain;thenameofthefollowingfunctionis
displayed,andsoon.
ThelastfunctionStletsyouchoosewhethertosavetheconfiguration
made(Y)orexitwithoutsaving(no).Later,thedisplaywillresume
showingtheautomatedsystemstatus
You can go to St at any time. To exit programming,
simultaneously press F and -.
BASIC CONFIGURATION
Display
Function Default
dF
Loading predefined parameter sets
00 Neutralcondition
01 Minimummass
06 Maximummass
Beforeautomatedsystemstart-up,youmust
setthecorrectvalue,directlycorrelatedtothe
lengthofthebeamandthenumberandtype
of accessories installed. To determine said
value,refertoTables4and5onpage24
WARNING: Setting a mass default
lower than the one actually
installed could cause irreversible
damage to the bar and barrier
structure.
Ifyoudonotwishtomakeanyprogramming
changes, leave the value 00, otherwise
selectingavalueinvolvesloadingthechosen
predefined parameters set (see paragraph
5.2).
00
At
Currently loaded default
This menu indicates the currently loaded
defaultsetting.
Given that parameter dF has 00 as the
predefinedvalue(inordertoprovideaneutral
accessconditiontotheparameters),usingthe
valueinthismenumakesitpossibletoidentify
thecurrentlyconfigureddefaultsetting.
Read-only parameter
06
Display
Function Default
bu
BUS accessories menu
Forfunctionsassociatedwiththisparameter
seeparagraph5.3
no
LO
Operating logics
A Automatic
A1 Automatic1
E Semi-automatic
P Parking
PA Automaticparking
Cn Condo
CA Automaticcondo
C Dead-man
CU Custom
E
PA
Pause time
Is effectiveonly if an automatic logic is
chosen;thevalue can be set from O to
59 sec. in one second steps.Next,the
displaychangestominutesandtenthsofa
second(separatedbyadecimalpoint) and
timeisadjustedin10-secondstepsuptothe
maximumvalueof4.1minutes.
e.g.ifthedisplayshows2.5,thepausetime
willbe2minutesand50seconds.
20
So
Opening speed
Adjuststhebarrieropeningspeed.
00 Minimumspeed
10 Maximumspeed
WARNING: Setting an excessive speed
could cause irreversible damage to the
beam and barrier structure.
10
Sc
Closing speed
Adjuststhebarrierclosingspeed.
00 Minimumspeed
10 Maximumspeed
WARNING: Setting an excessive speed
could cause irreversible damage to the
bar and barrier structure.
02
L1
Loop 1
Activatingthisparameter,anyloopthatis
connectedtotheLoop1inputwillserveas
anOPENfunction.
Y Loop 1 enabled
no Loop 1 disabled
Note:Shouldthisfunctionbe disabled, the
detectionstatusoftheloopwillinanycase
remainavailableononeofthetwooutputs,
ifconfigured(see parameters o1... o4 in
AdvancedConfiguration)
no