SERVICE MANUAL
EVO FRONT LOADING DISHWASHER
This process is repeated until the tank is full (PT=0)
9.5.6. RUN CYCLE
With the encoder in the position P1, P2, or P3, if the tank is full (PT=0) and the door closed (IP=1), when the START
button is pressed, the selected programme starts to run, and the machine active led (L2).
When the cycle starts, the wash pump is activated (MBL=1) for the time defined for the cycle (configured by DIP1
and DIP3) minus the drain and rinse time.
The rinse time will depend on the configuration of the DIP4.
If DIP4=0: Rinse time=14 sec.
If DIP4=1: Rinse time=11 sec.
If the door is opened at any time (IP=0), a PAUSE is made in both the operation and the countdown time, and
normal operation is restored as soon as the door is closed.
In addition, if START is pressed again during a cycle, the programme will be aborted.
9.5.7. DISHWASHER WITHOUT AIR BREAK
If the “Thermostop” is active and the boiler has not reached the required temperature (TC=1), the wash pump will
continue active (MBL=1) until the required temperature is reached in the boiler (TC=0) or until the established time-
out period has ended (8 minutes), going on to the drain and rinse phase and activating the drainage pump (BD=1)
the whole time.
After 5 seconds draining, the rinse cycle starts (the drainage pump remains active (BD=1)), maintaining the fill
output active (V=1).
9.5.8. HYDRAULIC DIAGRAM OF DISHWASHER WITHOUT AIR BREAK