9.5.9. DISHWASHER WITH AIR BREAK
In machines with Air Break, if the “Thermostop” is active, the wash pump will continue active (MBL=1) until the
required temperature and level are reached in the boiler (TC=0 and PC=0) or until the established time-out period
has ended (8 minutes), going on to the drain and rinse phase.
After 5 seconds draining, the rinse cycle starts (the drainage pump remains active (BD=1)), maintaining the rinse
pump active (V=1) with the Machine Ready LED active (LMP=1).
Note that it will never be possible to fill the boiler (Vreg=1) while the rinse pump is running (V=1).