PROBE CONNECTION
The CNC has two probe inputs (of 5Vdc and 24Vdc) at connector X3.
Depending on the type of connection applied the g.m.p. “PRBPULSE” (P39) must be set, indicating
whether it operates with the leading edge or trailing edge of the signal which the probe provides.
Probe with “normally open contact” output,
Probe with “normally closed contact” output.
Interface with output in open collector Connection to +5 V.
Interface with output in open collector Connection to +24 V.
Interface with output in PUSH-PULL.
Active high (with an up flank).
Active high (with an up flank).
Active low (with a down flank).
Active low (with a down flank).
The active flank depends on the
interface