FS10 Series
50 Fluid Components International LLC
Safety
Instructions
for the use of the FS10
flow meter
in Hazardous
Areas
Approval
LC 16ATEX14269X / IECEx LC 16.0006X
for:
Category II 3 G for Gas
protection
Ex nA IIC T4 Gc
Category II 3 D for Dust
protection
Ex tc IIIC T81°C Dc, IP64
The FS10 series consist of a sensing element and associated integral or remote mounted electronics.
Relation between ambient temperature, process temperature and temperature class is as follows:
1) Ambient temperature range (Ta): -40°C … +71°C
2) Maximum process temperature (Tp): 121°C (integral version)
260°C (remote version)
3) Electrical data: Power supply - 21.5…30 VDC, 2.5 watts max.
Dansk
Sikkerhedsforskrifter
Italiano
Normative di sicurezza
Deutsch
Sicherheitshinweise
Nederlands
Veiligheidsinstructies
English
Safety instructions
Português
Normas de seguraa
Υπ
Υπ_δεί_εις ασφαλείας
Español
Instrucciones de seguridad
Suomi
Turvallisuusohjeet
Svenska
Säkerhetsanvisningar
Français
Consignes de sécurité
DK Dansk -
Sikkerhedsforskrifter
Disse sikkerhedsforskrifter lder for Fluid Components, FS10
EF-typeafprøvningsattest-nr.
LC 16ATEX14269X / IECEx LC 16.0006X
(attestens nummer typeskiltet) er egnet til at blive benyttet i eksplosiv atmosfære kategori II 3 GD.
1) Ex-anlæg skal principielt opstilles af specialiseret personale.
2) FS10 skal jordforbindes.
D A
Deutsch - Sicherheitshinweise
Diese Sicherheitshinweise gelten für die Fluid Components, FS10 flow meter gemäß der
EG-Baumusterprüfbescheinigung
Nr.
LC 16ATEX14269X / IECEx LC 16.0006X
(Bescheinigungsnummer
auf dem Typschild) der Kategorie II 3 GD.
1) Die Errichtung von Ex-Anlagen muss grundsätzlich durch Fachpersonal vorgenommen werden.
2) Der FS10 muß geerdet werden.
GB IRL English - Safety
instructions
These safety instructions are valid for the Fluid Components, FS10 flow meter to the EC type approval certificate no LC 16ATEX14269X /
IECEx LC 16.0006X (certificate number on the type label) for use in potentially explosive atmospheres in Category II 3 GD.
1) The installation of Ex-instruments must be made by trained personnel.
2) The FS10 must be grounded.
GR Υπ_δεί_εις
ασφαλείας
Αυτές οι οδηγίες ασφαλείας ισχύουν για τα Ροόµετρα της Fluid Components τύπου FS10 που φέρουν Πιστοποιητικό Εγκρίσεως
Ευρωπαϊκής Ένωσης, µε αριθµό πιστοποίησης LC 16ATEX14269X / IECEx LC 16.0006X (ο αριθµός πιστοποίησης βρίσκεται πάνω στην
ετικέτα τύπου του οργάνου) για χρήση σε εκρηκτικές ατµόσφαιρες της κατηγορίας II 3 GD.
1) Η εγκατάσταση των οργάνων µε αντιεκρηκτική προστασία πρέπει να γίνει από εξειδικευµένο προσωπικό.
2) Το όργανο τύπου FS10 πρέπει να είναι γειωµένο.