8. Service functions and error messages
126 Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH
Error message
Main
index
Sub-
index
Meaning of error
message
Measures Error reaction
3 DeviceNet communication
error
Send buffer overflow PS off
1)
4 DeviceNet communication
error
IO message could not be sent PS off
1)
5 DeviceNet communication
error
Bus off PS off
1)
6 DeviceNet communication
error
Overrun in the CAN controller PS off
1)
0 DeviceNet general
error
Common error: Communication has been
activated even though there is no
extension module plugged in. The
DeviceNet extension module is attempting
to read an unknown KO. Unknown
DeviceNet error.
PS off
1)
DeviceNet initialisation
error
DeviceNet extension module initialisation
error: Node number exists twice
65
1
DeviceNet communication
error
IO connection timeout
PS off
1)
2 General arithmetic error The FHPP factor group cannot be
calculated correctly.
PS off 70
3 Operating mode error Prohibited change of operating mode, e.g.
torque control for CMMSST in open-loop-
controlled operation or parametrisation
mode in FHPP, change in operating mode
when output stage is released.
PS off
1)
79 0 RS232 communication
error
Overrun when receiving RS232 commands. PS off
1)
1)
PS off
QStop
Warn
Ignore
Changeable with FCT
Switch off power section
Fast stop
Warning
Ignore
Table 8.2 Error messages