3. Product description
Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH 51
3.5.3 Setpoint processing
Through setpoint selection, an additional setpoint can be plugged in via the correction
value with the control interface RS-485.
Depending on the prefix, the speed setpoint is disabled via the signal of the
corresponding limit switch input. The limit switch inputs also affect the ramp generator
for the speed setpoint.
The speed setpoint is converted by the controller into the corresponding frequency to
actuate the stepper motors.
The speed setpoint (without the correction value) is reached via a setpoint ramp. Four
acceleration ramps can be configured in the range of one controller cycle of up to approx.
10 s. The setpoint ramp can be deactivated.
3.5.4 Suppression of ranges
When speeds close to the mechanical natural resonance are reached, there is a speed
jump so that the resonance is skipped. The mechanical natural resonance and the
bandwidth (hysteresis) can be set. Up to three speed ranges can be hidden.

Table of Contents

Other manuals for Festo CMMS-ST-C8-7-G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMS-ST-C8-7-G2 and is the answer not in the manual?

Festo CMMS-ST-C8-7-G2 Specifications

General IconGeneral
BrandFesto
ModelCMMS-ST-C8-7-G2
CategoryController
LanguageEnglish

Related product manuals