4. Functional safety engineering
Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH 97
A typical measurement curve could look as follows.
Graphically read brake time: 210 ms.
Fig. 4.9 Typical measurement curve for determining the brake time
4.3.13 Setting the delay time
The delay time of the PILZ PNOZ XV2P can be set manually at the device. This delay time
must be larger than the determined brake time. Otherwise, the drive would not brake in
the defined manner, but run out uncontrollably.