A. Technical data
128 Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH
A. Technical data
A.1 General information
Area Values
Storage
temperature:
-25°C to +70°C Permitted temperature ranges
Operating
temperature:
0°C to +40°C
+40°C to +50°C with power
reduction 4% / K
Permitted installation height Up to 1000 m above sea level
1000 to 3000 m above sea level with power
reduction
10% / 1000 m
Air humidity Relative humidity up to 90%, non-condensing
Protection class IP20
Contamination class 1
CE-conformity with low-voltage guideline:
EMC law: Current oscillations:
EN 50 178
EN 61 800 - 3
EN 61 000 - 3 - 2
Further certifications UL / CSA
Specifications on EN ISO 13849-1
PL (performance level) d
MTTFd (Mean Time To Failure dangerous)
Channel 1 (switching off PWM signals via X1)
Channel 2 (switching off driver supply via X3)
617.06 years
2853.88 years
PFH (Probability of Failure per Hour) 8.32 x 10
-8
Table A.1 Technical data: Ambient conditions and qualifications
Features Values
Device dimensions (H*W*D) 160x50x160 mm
Weight 2.0 kg
Table A.2 Technical data: Dimensions and weight
Features Values
Current regulator 20 μs
Speed regulator 200 μs
Position controller 400 μs
Table A.3 Technical data: Cycle times

Table of Contents

Other manuals for Festo CMMS-ST-C8-7-G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMS-ST-C8-7-G2 and is the answer not in the manual?

Festo CMMS-ST-C8-7-G2 Specifications

General IconGeneral
BrandFesto
ModelCMMS-ST-C8-7-G2
CategoryController
LanguageEnglish

Related product manuals