5. Maintenance and conversion
5−4
Festo P.BE−VTSA−44−EN en 0509NH
5.1 General precautionary measures
Warning
Sudden unexpected movements of the connected actua
tors and uncontrolled movements of loose tubing can
cause injury to human beings or damage to property.
Before carrying out installation and maintenance work,
switch off the following:
· the compressed air supply
· the operating and load voltage supplies.
Please note
Handle all modules and components of the valve terminal
with great care.
Note especially the following when fitting components:
· Screws must be fitted accurately (otherwise threads will
be damaged).
· Screws must be fastened at first only by hand. Place the
screws so that the self−cutting threads are used.
· The specified torques must be observed.
· Screw connections must be fitted free of offset and
mechanical tension.
· Check the seals for damage (IP65).
· The contact surfaces must be dry and clean (sealing
effect, avoid leakage and contact faults).