4-4 FT-100/CI and FT-170/CI Operation Guide
Document 40275-0913
4.3 Performing Weekly Maintenance
4.3.1 Steps: Cleaning and Inspecting the Inspection Head
Housing
Complete these steps to clean and inspect the housing around the
inspection head.
1. Turn off the main power switch.
2. Inspect for damage including the name plate, safety
stickers, labels, and instruction plates.
3. Wipe with a clean, soft, damp cloth.
Do not wash with a high pressure nozzle.
Do not steam clean.
4.3.2 Steps: Inspecting the External Wiring and Conduit
for Damage
Complete these steps to inspect the external wiring and conduit.
1. Turn off the main power switch.
2. Check the external wiring between the sensors and the
FT-100/CI or FT-170/CI for damage. Check all connections
carefully to ensure that they are not loose.
3. Check that insulating sleeves are in place.
4. Report any problems to your service department.
4.3.3 Steps: Verifying the Beacon
Complete these steps to verify that the beacon is operating
correctly.
1. On the MASTER MENU, first select Diagnostic Displays, then
Test Beacon, and then press the Enter key on the control
panel.
2. Does the beacon flash?