Maintenance and Troubleshooting 4-11
Document 40275-0913
4.8 Diagnostic Messages
4.8.1 List
Diagnostic messages appear on the screen when inspection
problems arise. This section provides definitions for these
messages to help you unravel the problems.
Encoder Signal Failure
This is a high priority message. The encoder is present and cases
are moving through the trigger, yet there is no encoder signal.
Call your service department immediately.
Case Not Rejected (If Supplied With
Sensor)
No case has passed the reject verification sensor within the time
limit set for the reject verification gate. Call your service
department if this message persists.
False Trigger Signal
A trailing edge signal was received when a leading edge signal
was expected. The inspection trigger sensor was not correctly
triggered. Call your service department if this message persists.
Flap Rejects Alarm
This is a high priority message. The number of flap rejects
exceeds the maximum allowable in the Consecutive Reject Alarm
Settings. Call your service department if this message persists.
Note: Messages that contain the word “Alarm” indicate
inspection options that have programmable parameters.