4-12 FT-100/CI and FT-170/CI Operation Guide
Document 40275-0913
Radiation Detector Failure
This is a high priority message. The radiation detector is failing or
has failed. Call your service department immediately.
Radiation Rejects Alarm
This is a high priority message. The number of missing container
rejects or residual container rejects exceeds the maximum
allowable in the Consecutive Reject Alarm Settings. Call your
service department if this message persists.
Radiation Shutter Closed
The autoshutter did not open when the production line was
started and remains closed. Call your service department for
assistance.
High Flap Failure
The trigger beam is blocked or the sensor failed. Check the
trigger sensor for any blockage. Call your service department if
this message persists.
Leading Flap Failure
The trigger beam is blocked or the sensor failed. Check the
trigger sensor for any blockage. Call your service department if
this message persists.
Line Speed Too High
This message appears when the line speed is higher than when
the encoder was calibrated. The case profile lengths vary with
line speed and cause false missing container rejects. The encoder
might require re-calibration. Call your service department for
assistance.