Keypad Functions
General Information Note that if you enabled QUICK ARM for the partition (field
21), the [#] key
can be pressed instead of entering the partition's security code, for any of the
arming procedures (Away, Stay, Instant, Maximum, etc.). The security code is
always required, however, when disarming the system.
The keypad allows the user to arm and disarm the system, and perform other
system functions, such as bypassing zones, and display zone descriptors. Zone
and system conditions (alarm, trouble, bypass) are displayed in the Display
Window.
When an alarm occurs, keypad sounding and external sounding will occur,
and the zone(s) in alarm will be displayed on the keypad. Pressing any key
will silence the keypad sounder for 10 seconds. Disarming the system will
silence both keypad and external sounders. When the system is disarmed,
any zones that were in an alarm condition during the armed period will be
displayed (memory of alarm). To clear this display, simply repeat the disarm
sequence (enter the security code and press the OFF key) again.
The keypads also feature chime annunciation, and 3 panic key pairs, or
individual panic keys (depending on keypad type Ð see Panic Keys below), for
silent, audible, fire or personal emergency alarms. These keys can notify the
central station of an alarm condition, if that service is connected.
Arming Functions The following is a brief list of system commands. For detailed information
concerning system functions, refer to the User's Manual.
Disarmed, Not Ready ........ Before arming, the system must be in the
READY condition (all zones must be intact). If
the "NOT READY" message appears, press the
READY [
] key to display faulted zones.
Arming Away ...................... Enter code + AWAY [2].
Arming Stay........................ Enter code + STAY [3].
Arming Instant .................. Enter code + INSTANT [7].
Arming Maximum ............. Enter code + MAXIMUM [4].
Disarming ........................... Enter code + OFF [1].
Bypassing Zones ................ Enter code + BYPASS [6] + zone number(s).
Forced (Quick) Bypass ..... To automatically bypass all faulted zones (plus
(If enabled) zones 17, 30, and 31 if programmed), use the
"Quick Bypass" method: Enter code + BYPASS,
then wait for all open zones to be displayed.
Arm when display indicates ÒbypassÓ and
Òready to armÓ.
Chime Mode ........................ Enter code + CHIME [9].
To turn chime off, enter code + CHIME again.
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming
Mode
Exit
Delay
Entry
Delay
Perimeter
Armed
Interior
Armed
AWAY Yes Yes Yes Yes
STAY Yes Yes Yes No
INSTANT Yes No Yes No
MAXIMUM Yes No Yes Yes
Special AWAY Arming
(2-Partition Arming) In a 2-partition system, if the same master code is in effect for both
partitions, both partitions can be armed AWAY at the same time from either
partition's keypad. Both partitions must be Ready To Arm.
1. Enter: Master Code + [AWAY] + [AWAY]
2. Two beeps will sound as both partitions arm (with exit delay).

Table of Contents

Other manuals for First Alert FA162C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA162C and is the answer not in the manual?

First Alert FA162C Specifications

General IconGeneral
BrandFirst Alert
ModelFA162C
CategorySecurity System
LanguageEnglish

Related product manuals