Reviewing a Data Field/Erasing an Entry in a Data Field
Press [#] plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [
] plus Field No. + [
]. (Applies only to
fields
40Ð
46, and
94).
Interactive Mode Programming (
56,
80,
81,
82 and
83)
Typical prompt displayed
during interactive mode
programming
Enter Zn Num.
(00 = Quit) 01
ÊZone Number -
Press [
] plus interactive mode no. (for example,
56). The Alpha keypad
will display the first of a series of prompts requesting entries.
A detailed procedure (with displays of prompts) is provided in later sections
of this manual.
Interactive Mode Used To Program
56 Zone Programming Zone characteristics, report codes, alpha
descriptors and serial numbers
80 Relay Programming 4229 or 4204 Relay modules, or Powerline
Carrier devices
81 Zone List Programming Zone Lists for relay/powerline carrier activation
82 Alpha Programming Zone alpha descriptors
83 Sequential Mode 5800 series transmitter serial numbers
Loading Factory Defaults
To load the factory defaults, enter the programming mode, press
97, then
exit the programming mode.
Do not press
97 to load defaults if any programming has been done
previouslyÑdata already programmed into the system will be changed!
96 resets all the Subscriber Account numbers and CSID in preparation for
an initial download.
Programming System Setup Fields
The following program fields must be programmed before doing any zone
programming.
22 RF SYSTEM ÊÊ0ÊÊ Ê
Enter 1 if 5881/5882 RF receiver is being used; enter 0 if no receiver is
being used. Default is 0 (none).
25 WIRED ZONE EXPANSION ÊÊ0ÊÊ
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is 0.
Exiting the Programming Mode
99 allows re-entry into the program mode using Installer Code + 8 0 0.
98 inhibits re-entry into the programming mode using the Installer code.
(If Local Lockout is enabled in field *91, then re-entry to program mode
must be made by using Installer Code + 8 0 0. )

Table of Contents

Other manuals for First Alert FA162C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA162C and is the answer not in the manual?

First Alert FA162C Specifications

General IconGeneral
BrandFirst Alert
ModelFA162C
CategorySecurity System
LanguageEnglish

Related product manuals