–44–
Reviewing a Data Field/Erasing an Entry in a Data Field
Press [#] plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [
✱
] plus Field No. + [
✱
]. (Applies only to
fields
✱
40Ð
✱
46, and
✱
94).
Interactive Mode Programming (
✱
56,
✱
80,
✱
81,
✱
82 and
✱
83)
Typical prompt displayed
during interactive mode
programming
Enter Zn Num.
(00 = Quit) 01
ÊZone Number -
Press [
✱
] plus interactive mode no. (for example,
✱
56). The Alpha keypad
will display the first of a series of prompts requesting entries.
A detailed procedure (with displays of prompts) is provided in later sections
of this manual.
Interactive Mode Used To Program
✱
56 Zone Programming Zone characteristics, report codes, alpha
descriptors and serial numbers
✱
80 Relay Programming 4229 or 4204 Relay modules, or Powerline
Carrier devices
✱
81 Zone List Programming Zone Lists for relay/powerline carrier activation
✱
82 Alpha Programming Zone alpha descriptors
✱
83 Sequential Mode 5800 series transmitter serial numbers
Loading Factory Defaults
To load the factory defaults, enter the programming mode, press
✱
97, then
exit the programming mode.
Do not press
✱
97 to load defaults if any programming has been done
previouslyÑdata already programmed into the system will be changed!
✱
96 resets all the Subscriber Account numbers and CSID in preparation for
an initial download.
Programming System Setup Fields
The following program fields must be programmed before doing any zone
programming.
✱
22 RF SYSTEM ÊÊ0ÊÊ Ê
Enter 1 if 5881/5882 RF receiver is being used; enter 0 if no receiver is
being used. Default is 0 (none).
✱
25 WIRED ZONE EXPANSION ÊÊ0ÊÊ
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is 0.
Exiting the Programming Mode
✱
99 allows re-entry into the program mode using Installer Code + 8 0 0.
✱
98 inhibits re-entry into the programming mode using the Installer code.
(If Local Lockout is enabled in field *91, then re-entry to program mode