–40–
TERMINALS
ON CONTROL
EARTH
GROUND
21 22 23 24 25
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PREMISES
ANSWERING
MACHINE AND
PHONES
ANSWERING
MACHINE
TIP
RING
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
TIP
RING
(TIP)
(RING)
▲▲
INCOMING TELCO LINE
BROWN (TIP)
GREY (RING)
ON
GND
V+
GND
1 2 3
RELAY 1, SHOWN
“OFF”
NO NC C
4204 or 4229
RELAY MODULE
RING (TO TERM. 22 )
TIP (TO TERM. 21)
INPUT TRIGGER
REFER TO
AAV MODULE
INSTRUCTIONS
FOR CONNECTIONS
TO AUDIO SPEAKERS
AND MICROPHONE
13
14
15
16
GREEN (TIP)
RED (RING)
+ VDC
NOTE:
DO NOT USE
RELAY 1 FOR
ANY OTHER
PURPOSE.
EAGLE SECURITY
MODEL 1241
Figure 20. Connection Of AAV Unit When Not Using A FA4285 Phone Module
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ON
GND
+VDC
RING (TO TERM. 22 )
TIP (TO TERM. 21)
REFER TO
AAV MODULE
INSTRUCTIONS
FOR CONNECTIONS
TO AUDIO SPEAKERS
AND MICROPHONE
TERMINALS
ON CONTROL
EARTH
GROUND
21 22 23 24 25
PREMISES
ANSWERING
MACHINE AND
PHONES
ANSWERING
MACHINE
TIP
RING
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
TIP
RING
(TIP)
(RING)
▲▲
INCOMING TELCO LINE
GREY (RING)
BROWN (TIP)
GREEN (TIP)
RED (RING)
1 2 3 4
4285
V+
GND
1 2 3
RELAY 1, SHOWN
“OFF”
NO NC C
4204 or 4229
RELAY MODULE
13
14
15
16
NOTE:
DO NOT USE
RELAY 1 FOR
ANY OTHER
PURPOSE.
EAGLE SECURITY
MODEL 1241
Figure 21. Connection Of AAV Unit When Also Using A FA4285 Phone Module

Table of Contents

Other manuals for First Alert FA162C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert FA162C and is the answer not in the manual?

First Alert FA162C Specifications

General IconGeneral
BrandFirst Alert
ModelFA162C
CategorySecurity System
LanguageEnglish

Related product manuals