35
DMP10 / DMP20 Settings for measurement
Single Readings (default mode)
Measured reading acquisition after the probe is placed on the surface. The measured
readings are automatically saved in the batch (measurement file), provided the Save
Readings function is activated.
Free Running
Continuous measured reading display while the surface is being scanned with the
probe. Measured readings are not saved even if the Save Readings function is acti-
vated!
Select Free Running measuring mode if you want only an overview of the coating
thickness distribution.
To select a measuring mode
1. > Batch Modify > OK > More Settings > OK > Measure Mode > OK > select
desired mode > OK
Parameter is activated:
2. Exit the menu: , the settings are now made.
The Measurement view shows the for the activated free-running measur-
ing mode.
7.4 Save measured readings on/off
You can specify whether the measured readings are automatically saved in the open
batch.
Function activated (default mode)
The measured reading is automatically saved in the open batch with every measured
reading acquisition.
Function deactivated
The measured readings are automatically saved in the open batch only temporarily.
When a different batch is called or the gauge is switched off, the measured readings
are lost.
[ ]