36
Settings for measurement DMP10 / DMP20
To activate/deactivate the save measured reading function
1. > Batch Modify > OK > Save Readings > OK
Parameter is activated:
Parameter is deactivated:
2. Exit the menu: , the setting has now been made.
The Measurement view shows the icon to indicate that the measured read-
ing save function has been deactivated.
7.5 Air reference value automatic/manual acquisition
The air reference value references the zero point determination for the measure-
ment.
Zero point determination: measurement on the uncoated base material = coat-
ing thickness 0 (normalization, zero)
Air reference: Measurement in air = coating thickness infinite = saturation = air
reference value
To achieve a high measurement accuracy, the air reference value has to be mea-
sured on a regular basis.
You can choose between automatic (dynamic) and manual (static) acquisition of the
air reference value:
Dynamic (default mode)
Dynamic, automatic acquisition of the air value each time the probe is lifted off the
surface.
Static
Static, no automatic acquisition of the air value each time the probe is lifted off the
surface. The air reference value has to be measured manually at regular intervals.
Useful for measurements in small cavities or pipes where the minimum lift off
distance of the probe cannot be maintained within the cavity/pipe.
Default in Probe
Information about the acquisition method for the air reference value set in the probe
in the factory.
[ ]