23
1. Turn off the gas and disconnect power to the range.
2. Remove the grates from the range.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
3. Remove the burner cap and port ring from the
burner.
4. Remove the 1-1/16ʺ venturi nut from the simmer ring
and lift the ring off the burner base.
Burner Cap Port Ring Volcano
5. Remove the 13/16ʺ venturi from the burner base.
Venturi Nut
Venturi
Grates
6. Lift the burner base off the cooktop and disconnect the
wire from the electrode terminal.
Burner BaseElectrode Wire