34
4. To remove a dual fl ow valve (see the photo on the next
page):
a) Remove the burner switch (see step 3).
b) Remove the 7/16ʺ nut from the simmer gas line
and remove the line from the valve.
c) Remove the 9/16ʺ nut from the main burner gas
line and remove the line from the valve.
d) Remove the two clamp screws on the dual fl ow
valve and remove the valve from the manifold.
1. Turn off the gas and disconnect power to the range.
2. Remove the valve panel (see page 56 for the proce-
dure).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
3. To remove a burner switch (see the photo at the top of
the right column):
a) Disconnect the two wires from the burner switch
terminals.
b) Remove the c-clip from the dual flow valve
stem.
c) Pull the burner switch off the dual fl ow valve
Dual Flow Valve & Burner Switch
C-Clip Wire Connectors
SERVICING THE COMPONENTS
REMOVING A BURNER SWITCH & DUAL FLOW VALVE
WARNING