59
Refer to pages 52 (grill), 54 (griddle), 68 (IR), 74 (main
oven), and 76 (12ʺ oven) for the procedure for servicing
the ignitors.
1. Turn off the gas and disconnect power to the range.
2. Disconnect the white ignitor wire connector from the
thermal valve terminal, or from the ceramic nut wires.
3. Set the ohmmeter to the R x 10 scale.
4. Touch the ohmmeter test leads to the two ignitor wires.
The meter should indicate between 110 and 135 Ω.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
CONVECTION MOTOR
Refer to page 72 for the procedure for servicing the convec-
tion motor.
1. Turn off the gas and disconnect power to the range.
2. Disconnect one of the convection motor wires from
the ceramic nut.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the two motor wires.
The meter should indicate between 45 and 75 Ω.
IGNITOR
TESTING THE COMPONENTS
WARNING

Table of Contents