RGS-305 Model Only
INSTALLATION INSTRUCTIONS
CABINET PREPARATION
ABC D E FGH I J K
RGS-48 Models 28-1/8” 10-1/8” 2” 35-3/4” min.-37” max. 30-1/4” 44-1/2” 28-1/4” 1-5/16” 25” 27-3/8” 47-7/8”
RGS-36 Models 28-1/8” 10-1/8” 2” 35-3/4” min.-37” max. 30-1/4” 44-1/2” 28-1/4” 1-5/16” 25” 27-3/8” 35-7/8”
RGS-305 Models 28-1/8” 10-1/8” 2” 35-3/4” min. -37” max. 30” 44” 27-1/2” 1-5/16” 24-1/4” 26-3/4” 29-7/8”
0” Clearance
C
J
I
0 Clearance
B
A
F
C
H
E
D
G
36 Min. to
Combustibles Δ
12 Min. to
Combustibles Δ
without backguard
Δ As defined in the “National Fuel Gas Code” (ANSI Z223.1, lastest edition).
The horizontal surfaces of the range top (cooktop)
trim must not be below countertop level.
K
K
K
RGS-48 Models RGS-36 Models RGS-305 Model
A
B
CAUTION:
36
min. to
combustible
material
Δ
from cooking
surface
35-3/8
max. for level counter,
36-3/4
max. with range leveling
legs fully extended
12
min. to combustible
material Δ each side
min. 30 wide hood
18
Min.
13
Max
Δ As defined in the “National Fuel Gas Code”
(ANSI Z223.1, lastest edition).
The horizontal surfaces of the range top (cooktop)
trim must not be below countertop level.
gas supply
electrical supply
4 4
12 12
3-1/2
3-1/4
cooking surface