The outlet vent sits in the top right of the cavity liner, this carries the vapours up through the duct to the
cooling fan and is then expelled.
These models have valves on the inlet and outlet vents. The valves are operated by wax actuators and
are driven by the oven controller. This allows the venting rate to be customised to suit the oven function
being used by the customer, and helps eliminate condensation.
The Pyro version includes a catalytic converter in the outlet to reduce smoke and CO during a self clean
function.
High Spec Multi and Pyro
Inlet Valve
Outlet Valve

Table of Contents