EasyManua.ls Logo

FLENDER N-BIPEX BWN - Possible Faults

FLENDER N-BIPEX BWN
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
7.2 Faults - causes and rectification
38 Edition 09/2022 M3401-02en
WARNING
Physical injury
Injury from rotating parts.
Only carry out work on the coupling when it is not moving.
Secure the drive unit against being operated accidentally.
Attach a notice to the switch stating clearly that work is being carried out on the coup-
ling.
Before starting any work, make sure that the unit is free from loads.
Intended use
The coupling is only approved for the applications specified in these instructions. Please ob-
serve all the stipulations in section Intended use (Page17).
7.2.2.1 Possible faults7.2 Faults - causes and rectification
Fault Cause Rectification
Sudden changes in the noise level and/
or sudden occurrences of shocks
Wear of wearing parts Follow the instructions given in section
Replacing wearing parts (Page40).
Changed alignment Follow the instructions given in section
Correcting the changed alignment
(Page40).
Coupling not suitable for the operating
conditions.
Check the possible causes given in
section Unsuitable coupling (Page39).
Use a coupling that is suitable for the
operating conditions.
Incorrect assembly of the coupling.
Check the possible causes given in
sections Assembly-related causes
(Page39) and Specific installation-re-
lated and maintenance-related causes
(Page40).
Reassemble the coupling in accord-
ance with these instructions.
Please observe all the stipulations and
requirements given in chapter As-
sembly (Page25).
Incorrect maintenance of the coupling.
Check the possible causes given in
sections Maintenance-related causes
(Page40) and Specific installation-re-
lated and maintenance-related causes
(Page40).
Please observe all the stipulations and
requirements given in chapter Servicing
(Page43).
Presence of vibration Coupling not suitable for the operating
conditions.
Check the possible causes given in
section Unsuitable coupling (Page39).
Use a coupling that is suitable for the
operating conditions.

Table of Contents

Related product manuals