EasyManua.ls Logo

Flexim FLUXUS G809 - Page 43

Flexim FLUXUS G809
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Installation
FLUXUS G809 6.2 Transducers
43
UMFLUXUS_G809V2-2EN, 2020-06-25
Quick release clasp
Insert the tension strap into the tension strap clamp and the metal spring, see Fig. 6.20 and Fig. 6.21.
Position the clasp, the tension strap clamp and the metal spring on the pipe, see Fig. 6.19:
on a horizontal pipe, mount the tension strap clamp on the side of the pipe, if possible
mount the metal spring opposite to the tension strap clamp
Place the tension strap around the pipe and insert it into the clasp, see Fig. 6.21.
Tighten the tension strap.
Tighten the clasp screw.
Ratchet clasp
Insert the tension strap into the tension strap clamp and the metal spring, see Fig. 6.23.
The metal spring does not have to be
mounted on:
steel pipes
pipes with an outer pipe diameter < 80 mm
pipes that are not subjected to significant temperature fluctuations
Position the ratchet clasp, tension strap clamp and metal spring (if necessary) on the pipe, see Fig. 6.19:
on a horizontal pipe, mount the tension strap clamp on the side of the pipe, if possible
mount the metal spring (if necessary) opposite to the tension strap clamp
Place the tension strap around the pipe and pass it through the slot of the clasp screw, see Fig. 6.24.
Tighten the tension strap.
Cut off the protruding tension strap, see Fig. 6.24.
Tighten the clasp screw.
Fig. 6.20: Tension strap with tension strap
clamp
Fig. 6.21: Tension strap with quick release
clasp and metal spring
1 tension strap clamp 1 clasp screw
2 metal spring
Fig. 6.22: Tension strap with band clamp
clasp
1 clasp screw
Caution!
The edge of the tension strap is very sharp.
Risk of injury!
Debur sharp edges.
Wear the required personal protective equipment. Observe the applicable rules.
1
2
1
1

Table of Contents