6 Mounting
FLUXUS H721 6.2 Transducers
35
UMFLUXUS_H721V1-5EN, 2022-05-15
6.2.2.2 Transducer arrangement
The transducers can be arranged in the mounting rails in different ways:
6.2.2.3 Mounting the transducers of type ****LI**
If the nameplate of the transducers ****LI** is removed from the transducer cable during installation, it has afterwards to be
remounted and fixed to the transducer cable using the provided cable tie. The heat shrink tubing must not be reused.
Fig. 6.9: Transducer arrangement in mounting rails
Fig. 6.10: Nameplate on the transducer cable
1 transducers
2 nameplate
3 heat shrink tubing
4 cable tie
reflection arrangement, 1 rail
reflection arrangement, 2 rails
diagonal arrangement, 2 displaced
rails
diagonal arrangement, 2 parallel rails
before mounting: after mounting:
11
22
3
4